Procurement Summary
State : Maharashtra
Summary : 12106 - Disposable Tube Drain; Sterile; Pvc; with Radio-Opaque Line / Marking; "Size of Chest Tube on French Catheter Scale (Fr)-28, Effective Drainage Length (Edl) (Cms)-45, General Chest Tube Utility...
Deadline : 28 Nov 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 110460544
Document Ref. No. : H1242970
Financier : Self Financed
Purchaser Ownership : Public
Document Fees : Refer Document
Tender Value : Refer Document
EMD : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
12106 - DISPOSABLE TUBE DRAIN; STERILE; PVC; WITH RADIO-OPAQUE LINE / MARKING; "Size of chest tube on French catheter scale (Fr)-28, Effective drainage length (EDL) (cms)-45, GENERAL Chest Tube Utility- Adults, Stopper for size 14 Fr to 30 Fr -YES Sterile- yes Method of Sterilization -ETO MATERIAL Material of the tube ( Non-toxic, Medical grade), Pyrogen free, Pthalate free and Latex free - yes CONSTRUCTION Kink Resistant Thermosensitive Tube - YES Size of lateral perforation(drain) holes should not be more than 1/4th of tube size (Fr) and should not affect on tube tensile strength - yes No of lateral perforation (drain) holes in the section of the tube which resides inside the patient(Nos) 6 A radio opaque stripe which outlines the first drainage hole and also confirmation of placement on x-ray yes MARKING Marking distance along the length of the tube YES"
12106 - DISPOSABLE TUBE DRAIN; STERILE; PVC; WITH RADIO-OPAQUE LINE / MARKING; "Size of chest tube on French catheter scale (Fr)-28, Effective drainage length (EDL) (cms)-45, GENERA L Chest Tube Utility- Adults, Stopper for size 14 Fr to 30 Fr -YES Sterile- yes Method of Sterilization -ET O MATERIAL Material of the tube ( Non-toxic, Medical grade), Pyrogen free, Pthalate free and Latex free - yes CONSTRUCTION Kink Resistant Thermosensitive Tube - YES Size of lateral perforation(drain) hole s should not be more than 1/4th of tube size (Fr) and should not affect on tube tensile strength - yes N o of lateral perforation (drain) holes in the section of the tube which resides inside the patient(Nos) 6 A radio opaque stripe which outlines the first drainage hole and also confirmation of placement on x-ray yes MARKING Marking distance along the length of the tube YES" ]
Contract Category: Expenditure
Contract Type : Goods
Tender Type : Limited - Indigenous
Contract Category : Expenditure
Evaluation Criteria : Itemwise/Consigneewise
Bidding System : Single Packet
Pre-Bid Conference Required : No
Pre-Bid Conference Date Time : Not Applicable
Tendering Section : SURGICAL
Inspection Agency : CONSIGNEE
Publishing Date / Time : 21/11/2024 13:16
Procure From Approved Sources : Yes
Approving Agency : Rly. Board
Closing Date Time : 28/11/2024 11:00
Validity of Offer ( Days) : 60
Ranking Order for Bids : Lowest to Highest
Advertised Value :
Tender Doc. Cost (INR) : 0.00
Earnest Money (INR) : 0.00
Consignee MD/ BYCULLA, CR Maharashtra 100.00 Numbers
Documents
Tender Notice
viewNitPdf_4780668.pdf
5181052.pdf
5181056.pdf
5181066.pdf
5181063.pdf
5181061.pdf