Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) -... Tender

INDIAN COAST GUARD has floated a tender for Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - Icgs C-412; E 120, Qty: 5. The project location is South Andaman, Andaman and Nicobar Island (UT), India. The reference number is GEM/2025/B/6114787 and it is closing on 11 Apr 2025. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Expired Tender

Procurement Summary

State : Andaman and Nicobar Island (UT)

Summary : Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - Icgs C-412; E 120, Qty: 5

Deadline : 11 Apr 2025

Other Information

Notice Type : Tender

TOT Ref.No.: 117244665

Document Ref. No. : GEM/2025/B/6114787

Competition : NCB

Financier : Self Financed

Purchaser Ownership : Public

Document Fees : Refer Document

Tender Value : Refer Document

EMD : Refer Document

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-412; E 120 Both sea chest strainers corroded and thinned down resulting in excess accumulation of sea weeds Deteriorated strainers cause insufficient sea water su.., Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-412; E 121 Chequered plates carpet area approx 12 mtrs in engine room and water Jet are highly rusted deteriorated All plates along with supporting base frame riv.., Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C-412; E 122 08 in nos quick shut off valve not operating from FM 200 compartment & port catwalk view loosened broken wire Wire to be fixed with QSV by cutting join.., Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; E 123 Sea water leakage observed in overboard flange of AC system flange to be fabricated and affixed as per sample material AL Pressure testing upto 1 5 tim.., Repair, Maintenance, and Installation of Plant/ Systems/Equipments (Version 2) - ICGS C 412; L 131 Illumination light on ships name plate at Superstructure observed defective The same to be repaired renewed and system to be proved; Service Provider
Quantity Required: 5
Start Date: 04-04-2025 10:31 PM
End Date: 11-04-2025 9:00 AM

Documents

 Tender Notice

Bid_Document_7711665.pdf


Neshcap