NON-CITY DEPARTMENTS (PUBLIC/PRIVATE OPPORTUNITIES), MAYOR'S OFFICE OF HOUSING has floated a tender for 2901-2929 16Th Street Rehab - Arch.. The project location is USA and the tender is closing on 28 Oct 2024. The tender notice number is SFGOV-0000009822, while the TOT Ref Number is 108032025. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : 2901-2929 16Th Street Rehab - Arch.

Deadline : 28 Oct 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 108032025

Document Ref. No. : SFGOV-0000009822

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

10/01/2024 - Addendum 4 issued 09/18/2024 - Addendum 3 issued 09/11/2024 - Addendum 2 issued 08/26/2024 - Addendum 1 issued 1. Project Summary: Voluntary seismic retrofit to meet upcoming non-ductile structural retrofit ordinance on a Historic class A building, include commercial and residential accessibility and T24 upgrades. 2. Scopes of work: 2.1. Pre-Design: Owner-s Consultants o CASP Inspection Report: Include only the commercial units that are not already compliant with the Accessible Business Entrance (ABE) Requirements. This report will determine the need for Civil Engineering if sidewalk modifications permit is required o Structural Survey: Dimensioned as-builts and framing plans including the following listed items. (Owner wants to ensure compliance with the NDC Ordinance when the ordinance is published)  Floor framing plans for lower, ground, second, third and roof levels  Elevations, sections, and dimensional details, as required.  Identification of material of structural members (include exploratory demolition) o Geotechnical Report 2.2. Design: Architect and Architect-s Consultants o Structural Design: An initial structural report and a conceptual design was produced - please refer to attachments A and B  Review structural survey  Determine if the structural retrofit will be voluntary or mandatory per the upcoming NDC ordinance  Provide a structural retrofit design per the Engineering standard for retrofit: Structural Collapse Prevention at the BSE-1E level and address specific deficiencies at over 54% of BPOE structural objective. o Architectural Role and Design  Select and contract with the subconsultants who have submitted proposals associated with this RFP. Solicit for subconsultants as needed beyond structural engineer and T24.  Include consultant coordination, waterproofing design, title 24, and any other required information and coordination to complete a full permit application packet, including histor...
Start Date : 08/02/2024 5:00PM PDT
Due Date : 10/28/2024

Documents

 Tender Notice


Procurement Documents for USA

Access a comprehensive library of standard procurement documents specific to USA. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in USA

Explore Procurement Documents for USA


Want To Bid in This Tender?

Get Local Agent Support in USA and 60 More Countries.

View All The Services


View Tenders By


Publish Tenders


Have Any Dispute With The Purchaser?