Procurement Summary
Country : USA
Summary : 6515 Hearing Aid Analyzers and Skull Simulators
Deadline : 17 Dec 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 111856812
Document Ref. No. : 36C24625Q0251
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
Page 3 of 3DEPARTMENT OF VETERANS AFFAIRSNetwork Contracting Office 6 (NCO 6)Sources Sought Hearing Aid Analyzers and Skull Simulators for Wake County VA Outpatient Clinic (VA-25-00014681)Responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Additionally, the Government reserves the right to revise the requirements of the proposed action before the release of any associated solicitation. This notice is not a Request for Proposals (RFP) or a Request for Quotes (RFQ). OVERVIEW The Department of Veterans Affairs, Network Contracting Office 6 is conducting market research to identify potential sources for the delivery of Hearing Aid Analyzers and Skull Simulators to the Wake County VA Outpatient Clinic located at 2700 Benson Road, Garner, NC 27529. See scope of work. Forward all questions to the Contracting Officer identified below.SCOPE OF WORKWake County VA Outpatient Clinic is requesting contractors to provide brand name or equal equipment that meets or exceeds the physical, functional, and performance of the listed salient characteristics in this section. The equipment feature is essential to the technical requirements to meet the need of different departments/services.PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities:M0020 Hearing Aid Analyzer Audioscan Verifit 2 Must have the following: Control Unit Display type LED backlit active color Display size 12.1 in. diagonal Hearing Aid Test Box Stereo headphones monitor amplifier - 250 mW into 16 ohms, L/R Power amplifiers 2 @ 5 watts each Simultaneous stimulus channels 2 Simultaneous measurement channels 2 Temperature (storage) -20 to +60 C Relative humidity (non-condensing) 5% to 95%Atmospheric pressure 800 1060 hPA Power source 100 240V, 47 63Hz, 1.35A Connectors: 1 - Ethernet (RJ45) 5 - USB 1 - HDMI 2 - External speakers (RCA) 1 - Display unit/Test box interconnection (H...
Active Contract Opportunity
Notice ID : 36C24625Q0251
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: 246-NETWORK CONTRACTING OFFICE 6 (36C246)
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Dec 15, 2024 07:27 pm EST
Original Response Date: Dec 17, 2024 05:30 pm EST
Inactive Policy: Manual
Original Inactive Date: Jan 01, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
NAICS Code: 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
Place of Performance: Wake County VA Outpatient Clinic Garner, NC, 27529 USA
Documents
Tender Notice
36C24625Q0251.docx