BGIS - PWGSC RP1 has floated a tender for Ahu-1 Replacement. The project location is Canada and the tender is closing on 11 Jul 2024. The tender notice number is , while the TOT Ref Number is 102570832. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Canada

Summary : Ahu-1 Replacement

Deadline : 11 Jul 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 102570832

Document Ref. No. :

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Contractor services are to complete the upgrade of AHU in the mechanical room located in the mechanical penthouse of Oxford Building as per the bid package, including equipment, supervision, testing, tools, labour, materials, consumable and installed materials, and services.AHU-1 replacement of the air handling unit includes the following: Replacement Air Handling Unit, complete with supply fan(s), two-stage filters with electronic type final filter (MERV 15 equivalent), humidification dispersion tubes, direct-exchange cooling coil, heat recovery run-around loop preheat coil, dampers, actuators and control devices for temperature, humidity, and pressure. Supply Fan and Return Fan VSDs disconnects replacement. The installation of load reactors and harmonic filters is to be added where applicable. Replacement Condensing Unit on the roof level Replacement Humidifier on the Penthouse level The installation of the preheat coil and associated piping, complete with circulating pump, valves and insulation. The installation of control dampers and actuators at relief air openings Temporary Air Handling Unit will meet building demand throughout the duration of construction. Rebalancing of the AHU system, including all floor-level VAVs. Any necessary Mechanical/Electrical connections. Any required abatement to make the work area safe. Bidders are advised of the following requirements relating to Asbestos Abatement work in BC: Certification Requirements Bidder: According to the new standa...
Reference Number : 0000272223
Location : Canada, British Columbia, Northern BC
Job Location : Oxford Building – 280 Victoria Street, Prince George, BC
Description : Contractor services are to complete the upgrade of AHU in the mechanical room located in the mechanical penthouse of Oxford Building as per the bid package, including equipment, supervision, testing, tools, labour, materials, consumable and installed materials, and services.AHU-1 replacement of the air handling unit includes the following: Replacement Air Handling Unit, complete with supply fan(s), two-stage filters with electronic type final filter (MERV 15 equivalent), humidification dispersion tubes, direct-exchange cooling coil, heat recovery run-around loop preheat coil, dampers, actuators and control devices for temperature, humidity, and pressure. Supply Fan and Return Fan VSDs disconnects replacement. The installation of load reactors and harmonic filters is to be added where applicable. Replacement Condensing Unit on the roof level Replacement Humidifier on the Penthouse level The installation of the preheat coil and associated piping, complete with circulating pump, valves and insulation. The installation of control dampers and actuators at relief air openings Temporary Air Handling Unit will meet building demand throughout the duration of construction. Rebalancing of the AHU system, including all floor-level VAVs. Any necessary Mechanical/Electrical connections. Any required abatement to m...

Documents

 Tender Notice