Procurement Summary
Country : Canada
Summary : Ahu-1 Replacement Oxford Building - 280 Victoria Street Prince George, Bc
Deadline : 09 Feb 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 95029130
Document Ref. No. :
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Upgrade of AHU in Mechanical room located in the mechanical penthouse of Oxford Building.AHU-1 replacement of air handling unit, including the following:a) Air Handling Unit 1 replacement of air handling unit, including the following:b) Replacement Air Handling Unit, complete with supply fan(s), two-stage filters with electronic type final filter (MERV 15 equivalent), humidification dispersion tubes, direct-exchange cooling coil, heat recovery run-around loop preheat coil, dampers, actuators and control devices for temperature, humidity, and pressure.c) Supply Fan and Return Fan Variable Speed Drives (VSDs) disconnects replacement.d) Installation of load reactors and harmonic filters to be added where applicable.e) Replacement Condensing Unit on the roof levelf) Replacement Humidifier on the Penthouse levelg) The installation of the preheat coil and associated piping, complete with circulating pump, valves and insulationh) The installation of control dampers and actuators at relief air openingsi) Temporary Air Handling Unit to meet building demand throughout the duration of constructionj) Rebalancing of Air Handling Unit (AHU) system, including all floor level Variable Air Volumes (VAVs)k) Any necessary Mechanical/Electrical connections.
Reference Number : 0000262341
Location : Canada, All of Canada, All of Canada
Job Location : Oxford Building – 280 Victoria Street, Prince George, BC
Description : Upgrade of AHU in Mechanical room located in the mechanical penthouse of Oxford Building.AHU-1 replacement of air handling unit, including the following:a) Air Handling Unit 1 replacement of air handling unit, including the following:b) Replacement Air Handling Unit, complete with supply fan(s), two-stage filters with electronic type final filter (MERV 15 equivalent), humidification dispersion tubes, direct-exchange cooling coil, heat recovery run-around loop preheat coil, dampers, actuators and control devices for temperature, humidity, and pressure.c) Supply Fan and Return Fan Variable Speed Drives (VSDs) disconnects replacement.d) Installation of load reactors and harmonic filters to be added where applicable.e) Replacement Condensing Unit on the roof levelf) Replacement Humidifier on the Penthouse levelg) The installation of the preheat coil and associated piping, complete with circulating pump, valves and insulationh) The installation of control dampers and actuators at relief air openingsi) Temporary Air Handling Unit to meet building demand throughout the duration of constructionj) Rebalancing of Air Handling Unit (AHU) system, including all floor level Variable Air Volumes (VAVs)k) Any necessary Mechanical/Electrical connections.