Procurement Summary
Country : USA
Summary : Alto Instrument with Nicosystem Pro - Brand Name or Equal
Deadline : 12 Aug 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 105237011
Document Ref. No. : NIAID-SS-24-2225691
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
Introduction
This is a Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations. The purpose of this notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement.
Project Summary
The National Institute of Allergy and Infectious Diseases (NIAID), Vaccine Research Center (VRC) is seeking a Surface Plasmon Resonance Alto Instrument with Nicosystem Pro that measures binding kinetics of biomolecular interactions.
Specifically, NIAID, VRC is seeking one (1) Alto 16 Bundle (item 4032) Surface Plasmon Resonance Instrument with Nicosystem Pro (SPR) Instrument that can perform the following applications and meet the requirements listed below:
1) The instrument should use 2μL of sample and can perform five 3-fold serial dilutions of samples automatically.
2) The SPR instrument should feature versatile temperature controlled at 15oC, 25oC and 37oC.
3) It should be able to measure kinetic association rates up to 1 e9 1/(M*s).
4) The instrument should be able to measure kinetic dissociation rates between 1e-5 to 1.0 (1/s).
5) It should be able to measure equilibrium dissociation between 1e-12 to 1e-3 (M)
6) The kinetics cartridge should contain up to 16 unique surfaces for sample ligands and 48
sample analytes on a single kinetics cartridge.
7) The instrument should be compact, with dimensions of 1.5H x 1W x 1.5D ft (46H x 35W x 51D cm) and a weight 51 lbs (23 kg), making it easy to transport and saving valuable laboratory space.
8) It should ensure rapid transitions, with a nearly instantaneous transition time (9) The instrument should have two connectivity formats: Local Mode and Cloud Mode.
10) Its applications should include binding kinetics, screening, epitope binning/mapping, and quantitation under assay design.
11) The instrument should have direct and capture assay capabilities for...
Active Contract Opportunity Notice ID NIAID-SS-24-2225691 Related Notice Department/Ind. Agency HEALTH AND HUMAN SERVICES, DEPARTMENT OF Sub-tier NATIONAL INSTITUTES OF HEALTH Office NATIONAL INSTITUTES OF HEALTH NIAID
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Aug 02, 2024 05:14 pm EDT
Original Response Date: Aug 12, 2024 03:00 pm EDT
Inactive Policy: 15 days after response date
Original Inactive Date: Aug 27, 2024
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance: Bethesda, MD 20814 USA
Documents
Tender Notice