Procurement Summary
Country : USA
Summary : Chiller Repairs, Maintenance and Installation
Deadline : 28 Oct 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 108988103
Document Ref. No. : W913E525Q0002
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
This combined synopsis/solicitation for commercial items prepared in accordance with the format at FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued.
The solicitation number W913E525Q0002 is being issued as a request for quotation (RFQ).
The associated North American Industry Classification System (NAICS) code is 238220 - Plumbing, Heating, and Air Conditioning Contractors which has a size standard of $19M. This requirement is a Total Small Business Set-Aside in accordance with FAR 19.502-2.
The Cold Regions Research and Engineering Laboratory (CRREL) located at 72 Lyme Road, in Hanover, New Hampshire has a requirement to repair one (1) ammonia chiller system (hereafter referred to as the 23-ton #1 system) and conduct preventative maintenance on one (1) other identical ammonia chiller system (hereafter referred to as the 23-ton #2 system). Both 23-ton (#1 and #2) systems include a GEA model 125GMx compressor package charged with R-717. The GEA compressor skids are integrated into refrigeration packages to cool CRREL-s main cold glycol loop.
Requirement: The contractor shall furnish all labor, supervision, tools, materials, equipment, incidental engineering, transportation, and any other items and services necessary to perform the tasks under the 8, 000-hour service interval on the 23-ton #2 system and required repairs on the 23-ton #1 system. All work will follow guidance in each system-s respective manual and guidance from manufacturers regarding safety, materials used, and methods.
23-Ton #1 System: The Contractor shall replace the plate and frame heat exchanger with an equally capable heat exchanger that has excellent protection against both R-717 and water conditions. The specific model of heat exchanger to be installed shall be presented in the Contractor-s quote. F...
Active Contract Opportunity
Notice ID : W913E525Q0002
Related Notice
Department/Ind. Agency : DEPT OF DEFENSE
Sub-tier : DEPT OF THE ARMY
Major Command : USACE
Sub Command : OTHER DIVISION
Office: W2R2 COLD RGNS RSCH ENG LAB
General Information
Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
Original Published Date: Oct 21, 2024 01:12 pm CDT
Original Date Offers Due: Oct 28, 2024 12:00 pm CDT
Inactive Policy: 15 days after date offers due
Original Inactive Date: Nov 12, 2024
Initiative: None
Classification
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
Product Service Code: J041 - MAINT/REPAIR/REBUILD OF EQUIPMENT- REFRIGERATION, AIR CONDITIONING, AND AIR CIRCULATING EQUIPMENT
NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors
Place of Performance: Hanover, NH 03755 USA
Documents
Tender Notice
B08.pdf
B08.pdf
B08.pdf
B08.pdf