PHI UNIVERSITY CLINIC FOR PLASTIC AND RECONSTRUCTIVE SURGERY has floated a tender for Consumables for Microsurgery and Reconstructive Procedures. The project location is Macedonia and the tender is closing on 19 Mar 2024. The tender notice number is 03894/2024, while the TOT Ref Number is 98201560. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Macedonia

Summary : Consumables for Microsurgery and Reconstructive Procedures

Deadline : 19 Mar 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 98201560

Document Ref. No. : 03894/2024

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

PART 1 Micrograft gauze together with a cork pad intended for MEEK micrograft procedures for easy and fast skin transfer and rapid epithelization, with expansion 1:2, with dimensions 42x42mm. From the micrograft gauze, after cutting it is possible to form small squares of leather with dimensions 3x3mm, a total of 196 small squaresleather boots. Sterile packaging, 10 numbers in a box., PART 2 Micrograft gauze together with a cork pad intended for MEEK micrograft procedures for easy and fast skin transfer and rapid epithelization, with expansion 1:3, with dimensions 42x42mm. From the micrograft gauze, after cutting, it is possible to form small kleather squares with dimensions 3x3mm, a total of 196 small leather squares. Sterile packaging, 10 numbers in a box., PART 3 Micrograft gauze together with a cork pad intended for MEEK micrograft procedures for easy and fast skin transfer and rapid epithelization, with expansion 1:4, with dimensions 42x42mm. From micrograft. of the gauze, after cutting it is possible to form small squares of leather with dimensions 3x3mm, a total of 196 small squares of leather. Sterile packaging, 10 counts per box., PART 4 ​​Micrograft Gauze together with a cork pad designed for MEEK micrograft procedures for easy and fast skin transfer and rapid epithelizationand, with expansion 1:6, with dimensions 42x42mm. From the micrograft gauze, after cutting, it is possible to form small squares of leather with dimensions of 3x3mm, a total of 196 small squares of leather. Sterile package, 10 numbers in a box., PART 5 Micrograft Gauze together with a cork pad intended for MEEK micrograft procedureri for easy and fast transfer of skin and fast epithelization, with expansion 1:9, with dimensions 42x42mm. From the micrograft gauze, after cutting, it is possible to form small squares of leather with dimensions of 3x3mm, a total of 196 small squares of leather. Sterile packaging, 10 numbers in a box., SECTION 6 Microclip applicator with mminimum 15cm length, it must be reusable and can be sterilized in an autoclave, PART 7 Superfine microclip applicator with a minimum length of 15cm, it must be reusable and can be sterilized in an autoclave, PART 8 Titanium hemostatic microclip, Dimensions: 2.4mm diameter of open clip 3.1mm length of applied clip. One cartridge to contain 6 clips. Compatible with part 6, PART 9 Titanium hemostatic Superfine microclip. Dimensions: 1.5mm diameter of open clip 2.1mm length of applied clip. One cartridge to contain 6 clips. Compatible on del 7, PART 10 Coupler (Couplers) intended for veins and arteries with an outer diameter of 1.5 mm and a wall thickness of 0.5 mm or less, PART 11 Coupler (Couplers) intended for veins and arteries with an outer diameter of 1.5 mm and a thickness of wall of 2 mm or less, PART 12 Couplers intended for veins and arteries withouter diameter 2.5 mm and wall thickness of 0.5 mm or less, PART 13 Sterile surgical set for microvascular anastomoses of blood vessels (veins and arteries with outer diameter not less than 0.8 mm and not greater than 4.3 mm and thickness on the side of 0.5 mm or smaller ) for multiple use which treba to contain: - Titanium instrument for anastomosis that can be used multiple times - Aluminum grid for sterilization - Micro forceps length 18 cm /-3% with which the blood vessel can be turned over the pins. quantity 2 pieces- Double ended steel blood vessel gauge., PART 14 Radio-opaque silicon pad bolted with 1mm grids, non-reflective, no smaller than 50mm X 25mm, PART 15 EU skin stapler with 35 wide staples, which are deployed one by each activation of the stapler levers. When placing, the connectors should first penetrate through the coand then close to hold the tissue together. Diameter of the wire of the connectors = 0.5 mm; Dimension of closed staples 6.5mm x 4.5mm, ( /-5%), SECTION 16 EU leather stapler with 35 wide staples, which deploy one with each activation of the stapler levers. Connectsduring placement, the stitches should first penetrate the skin and then close to hold the tissue together. Diameter of the wire of the connectors = 0.5 mm; Closed Staple Dimension 5.7mm x 3.8mm, ( /-5%), PART 17 Leather Stapler Staple Remover for PART 15 and PART 16 for EU, Plasticwith metal tips, PART 18 Dermatome blades made of stainless steel, compatible with existing WATSON manual dermatome - or equivalent, dimension 18-21cm, PART 19 Electric dermatome blades made of stainless steel, compatible with existing PADGET SLIM electric dermatomeLINE S6 or equivalent, PART 20 Kirchner wires with double-sided stainless steel tip length 150 mm( /- 5%), diameter 1.0 mm; 1.25 mm; 1.5 mm, 1.6 mm and 2.0 mm, PART 21 Set of 10 Polycaprolactone and Lactic Acid Hyaluronic Acid Surgical Absorbable Sutures containing: P(LA/CL) Barbed Suture USP 2/0, EP 3, 190mm - 10 pieces Thread type: EP3 Length of thread: 190 millimeters Round tip hollow needle 20Gx150mm, straight - 10 pieces Round tip hollow needle 23Gx80mm, straight - 1 piece Lancet point needle 18Gx40mm Removable needle attachment, resorptive. (Permissible deviation of needle lengthand thread up to /- 5 %), PART 22 Set of 10 Polycaprolactone Lactic Acid Surgical Absorbable Sutures which should contain: P(LA/CL) Barbed Suture USP 2/0, EP 3, 190mm 10 PiecesLength of thread: 190 millimeters Hollow needle with round tip 20Gx150mm, straight - 10 pieces Hollow needle with round tip 23Gx80mm, straight - 1 piece Needle with lancet point 18Gx40mm Removable needle attachment. Absorbent. Needle type: blunt ( Allowable deviation of needle and thread length up to /- 5 %), PART 23 Set of 2 bidirectional absorbable polycaprolactone and lactic acid sutures which should contain: P(LA/CL) barbed threadUSP 2/0, EP 3, 500 mm - 2 pcs Suture type : EP3 Suture length: 500 mm Hollow double-sided blunt tip needle 21G x 110 mm Standard needle attachment Absorbent. Needle type: blunt Thread type: Two-way (Permissible deviation of needle and thread length up to /- 5 %),
CPV Descriptions: Medical consumables

Documents

 Tender Notice

Document_1.doc

Document_2.xlsx