Procurement Summary
Country : USA
Summary : Exhaust Stack Industry Chimney Inspection
Deadline : 20 Apr 2023
Other Information
Notice Type : Tender
TOT Ref.No.: 80612388
Document Ref. No. : SRNS32023ExHAUSTSTACKINSPECTION
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
****This is a REQUEST FOR INTEREST ONLY! This request does not constitute a request for proposal, request for quote, or invitation for bid. The intent of this request is to identify potential offerors for mark research purposes only*****
Savannah River Nuclear Solutions, LLC (SRNS), which manages and operates portions of the Savannah River Site (SRS) under a Department of Energy (DOE) prime contract, solicits expressions of interest from potential suppliers who have a strong background in Exhaust Stack and/or Industrial Chimney inspections.
The SRS complex is located approximately 15 miles south of Aiken, South Carolina and is 310 contiguous square miles.
Request for Information (RFI)
Scope Summary:
Provide an internal and external inspection of a 200- tall reinforced concrete stack exterior chimney and internal acid proof brick liner at an active nuclear facility. Inspection of a connecting structural steel breeching duct house and an adjacent 100- tall structural steel stair tower is also requested. The stack was built in 1954. Pictures nor drawing of the stack are not provided at this time.
The diameter at the base of the 291-H stack is approximately 18- decreasing to approximately 12--7” outer diameter at the top with approximately 12” thick walls at the base decreasing to approximately 6” thick walls at the top. The thickness of the acid proof brick lining is approximately 12” at the base extending to the 24--4” elevation, approximately 8” thick from the 24--4” elevation to the 149--4” elevation, and approximately 4” thick from the 149--4” elevation to the 199--4” elevation.
There are 3/8” diameter stainless steel threaded studs anchored into the exterior of the reinforced concrete stack at approximately 4- on center from the top of the stair tower to the top of the stack for inspection ladder purposes. There are no known studs on the interior of the reinforced concrete stack chimney or brick liner wall to attach ladd...
Active Contract Opportunity
Notice ID : SRNS32023ExHAUSTSTACKINSPECTION
Related Notice
Department/Ind. Agency : ENERGY, DEPARTMENT OF
Sub-tier : ENERGY, DEPARTMENT OF
Office : SRNS - DOE CONTRACTOR
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Mar 20, 2023 09:22 am EDT
Original Response Date: Apr 20, 2023 05:00 pm EDT
Inactive Policy: 15 days after response date
Original Inactive Date:
Initiative: None
Classification
Original Set Aside:
Product Service Code:
NAICS Code: 926150 - Regulation, Licensing, and Inspection of Miscellaneous Commercial Sectors
Place of Performance: Aiken, SC 29808 USA
Documents
Tender Notice