Procurement Summary
Country : USA
Summary : Huntington District Repair Fleet Service Barge Boiler Replacement
Deadline : 12 Aug 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 105270904
Document Ref. No. : BoilerSS_01
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. This notice does not constitute a commitment by the Government. All information submitted in response to this announcement is voluntary, and the Government will not pay for information requested nor will it compensate any respondent for any cost incurred in developing information provided to the Government.
The proposed NAICS code for this procurement is 238220 Plumbing, Heating and Air-Conditioning Contractors
The size standard: $19.mil; Product Service Code: N045
Location of project: Pittsburgh Engineering Warehouse and Repair Station, Pittsburgh, PA
The Huntington District Repair Fleet requires all material, equipment, labor, and supervision necessary for the installation of a new Weil McLain Model 0-588 Series 2 Oil-fired, Cast-Iron Sectional Boiler aboard a Repair Fleet Service Barge.
Additional Information: A new Weil McLain Model 0-588 Series 2 shall be provided by the contractor. All electrical cables shall be armored Marine cabling meeting the requirements of IEEE 45. Boiler shall include all pumps, valves, relief valves, piping, fittings, trim and appropriate controls exacting existing unit including low water cutouts. Package to include all hardware necessary to match the existing boiler. System shall match all fuel piping, circulating water, and flue. Shall include Start up and functional testing to provide a completely operational unit. Contractor shall conduct testing in accordance with the manufacturer-s recommendations and specifications to include verification of all shutdowns. The prime contractor shall have a minimum of 5 (five) years- experience in the installation of oil fired boilers similar to the boiler that is being provided.
DESIGN STANDARDS. All components shall meet the latest requirements of the following references:
• 46 CFR Parts, Subchapter J - Electrical Engineering
• Institute of Electrical and Electronics Engineers (IEEE) Std 45, ‘Reco...
Active Contract Opportunity
Notice ID : BoilerSS_01
Related Notice
Department/Ind. Agency : DEPT OF DEFENSE
Sub-tier : DEPT OF THE ARMY
Major Command : USACE
Sub Command : LRD
Office: W072 ENDIST HUNTINGTON
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Aug 05, 2024 08:51 am EDT
Original Response Date: Aug 12, 2024 01:00 pm EDT
Inactive Policy: 15 days after response date
Original Inactive Date: Aug 27, 2024
Initiative: None
Classification
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
Product Service Code: N045 - INSTALLATION OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT
NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors
Place of Performance: Pittsburgh, PA 15225 USA
Documents
Tender Notice