Procurement Summary
Country : USA
Summary : Power Systems Analysis Fy24
Deadline : 27 Mar 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 98195870
Document Ref. No. : FA805124R4005
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
The Contractor shall provide all labor, software, materials, tools, equipment, transportation, and supervision to collect field data, construct/update an electrical model, and generate analysis reports. The Contractor shall use the electrical model to perform a power flow analysis, cross connect capability evaluation, short circuit study, protective device coordination study, and arc flash hazard analysis at the following bases: Niagara ARS (New York), Beale AFB (California), Vandenberg AFB (California), Robins AFB (Georgia), Channel Islands ANG (California), Cheyenne Mountain (Colorado), Minneapolis ARS (Minnesota), Minneapolis ANG (Minnesota) Schriever SFB (Colorado), Eielson AFB (Alaska), Altus AFB, (Oklahoma), Sheppard AFB (Texas), Luke AFB (Arizona), Suwon AB, (South Korea), Gimhae AB (South Korea), Yokota AB (Japan), Incirlik AB (Turkey) In addition, the Contractor shall perform transformer oil sampling and testing, infrared inspections, and distribution reliability study at the installations listed above. The electrical distribution systems include items such as:
• Switching stations• Substations• Transmission, distribution, and service cables• Primary distribution equipment• Government owned power generating stations feeding directly into the primary distribution system.• Government owned renewable power generation feeding directly into the primary distribution system (such as generators, wind, and photovoltaic).
The study shall encompass the entire primary distribution system through the secondary up to and including the building service entrance disconnect and includes all motor loads 50HP or greater installed anywhere in the distribution system. Any medium voltage distribution and primary distribution equipment located on the interior of a building shall also be included in the study. This study shall not include:
• Standby or emergency generators serving individual facilities• Portions of the distribution system owned and oper...
Active Contract Opportunity Notice ID FA805124R4005 Related Notice Department/Ind. Agency DEPT OF DEFENSE Sub-tier DEPT OF THE AIR FORCE Major Command AIR FORCE MATERIEL COMMAND Sub Command AF INSTALLATION & MISSION SUPPORT CENTER Office FA8051 772 ESS PKD
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
Original Published Date: Mar 04, 2024 01:45 pm CST
Original Response Date: Mar 27, 2024 02:00 pm CDT
Inactive Policy: Manual
Original Inactive Date: Mar 28, 2024
Initiative: None
Classification
Original Set Aside:
Product Service Code: R425 - SUPPORT- PROFESSIONAL: ENGINEERING/TECHNICAL
NAICS Code: 541330 - Engineering Services
Place of Performance: Tyndall AFB, FL USA
Documents
Tender Notice
Request-for-Information--Power-Studies-FY24.pdf
Draft-PWS--Power-Studies-FY24.pdf