Procurement Summary
Country : Azerbaijan
Summary : Purchase of Machinery and Equipment
Deadline : 22 Nov 2023
Other Information
Notice Type : Tender
TOT Ref.No.: 91630186
Document Ref. No. : 73845
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Perfuzomat Perfuzomat, the device should be suitable for intravenous and enteral drug administration. - In order to understand the values well, the device should have a minimum 3.5" LCD screen. Maxium weight should be 1.7 kg. The device should be able to automatically determine the size of the injector and display it on the screen. Device depends on the companymust be able to be used with injectors that do not comply with international standards. The device must be compatible with 2/3/5/10/20/30/50/60ml injector types. Switching between modes on the device should be done with a single button. The device can work for about 6.5 hours with a rechargeable battery at a rate of 5 ml/hourhand, there should be an indicator on the front panel indicating that the battery is in a charging state. The battery should automatically turn on when the device loses power. The device should be capable of infusing in increments of 0.01 2300 ml/hour. The device changed the infusion rate in all modes without stopping the infusionshould be able to go. The device must have an output volume (volume) between 0.1-9999ml The device must be able to set a time between 1 minute and 99 hours and 59 minutes. Device Modes: Rate Mode, Dose Mode, Time Mode, Dose Time Mode, Sequential Mode, Intermittent Mode, Loading Dose Mode, Ramp Mode, Micro-infusion mode, TIVA mode should be. Congestion detection : 50 -1125 mmHg, should support 1 mmhg increase. DERS (Dose Error Reduction System) should support up to 5000 drug, color-coded drug names. It must be able to connect with the Central Monitoring System, supporting the HL7 protocolshould be clamped Disinfection : should support 49 kinds of detergents, Qty- 1, Unit of measure -pcs
UPS, 600/VA/360W battery UPS, 600/VA/360W battery, High quality according to standards, Qty- 400, Unit of measure -pcs
Computer for ups Computer ups, 650 VA, Qty- 50, Unit of measure -pcs
Air conditionerAir conditioner, 9000 BTU 20-30 KV. Installation and copper tube included, Qty- 1, Unit of measurement - quantity
Printer Printer, Device type- single laser, device function- print, copy, scan, Cartridge type...
Required number of bidders: 3
Date and time of opening of envelopes: 22.11.2023 13:01
Last date and time of submission of proposals: 2023-11-22
Documents
Tender Notice