Procurement Summary
Country : USA
Summary : Radiation Survey Meters
Deadline : 26 Jul 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 104457478
Document Ref. No. : 36C24624Q1127
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only. The Government will not pay for any information solicited.The VHA Network Contracting Office 6 (NCO 6) is conducting a market survey to find qualified and authorized vendors to supply Radiation Meter Survey Systems for the new Fredericksburg Health Care Clinic (HCC).The proposed NAICS 334519 is applicable to this acquisition; with a size standard of 600 Employees.Salient Characteristics: The Fredericksburg HCC will consider any items that meet the following Salient Characteristics. Interested vendors proposing similar items are required to submit an itemized description of their products to demonstrate they meet or exceed these requirements:ITEM 1: Meter, SurveyTotal Quantity: 6 eachBasis of Design: Ludlum Model 14C Survey Meter, Item# 48-1611Salient Characteristics: General Purpose handheld analog ratemeter with multiple separate radiation detectors.System must allow user to select between the internally mounted GM detector or an external GM or Scintillator detector. Dimensions: 6 ½ x 3 ½ x 8 ½ Weight: 3 ½ lbsVoltage: 900VPower: (2) D Cell BatteriesApplication: Alpha, Beta, and Gamma surveying Internal Detector Energy compensated GM (used with ×1000 scale only)Range: 0 to 20 mSv/hr (0 to 2000 mR/hr) Sensitivity: 200 cpm per mR/hrMust be compatible with any GM or Scintillation type operating on 900 VDC Detector Channels: External Detector: ×0.1 through ×100 range settingsInternal GM Detector: ×1000 setting Energy Response Within 15% of true value between 60 keV to 3 MeV (internal detector only) Linearity Reading within 10% of true value with detector connected Meter Dial: 0 - 2 mR/hr, 0 - 5 kcpm, BAT TESTMeter: 6.4 cm (2.5 in.) arc, 1 mA analog type Controls Rotary Selector Switch: Switches betwe...
Active Contract Opportunity Notice ID 36C24624Q1127 Related Notice Department/Ind. Agency VETERANS AFFAIRS, DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 246-NETWORK CONTRACTING OFFICE 6 (36C246)
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Jul 18, 2024 09:10 am EDT
Original Response Date: Jul 26, 2024 11:00 am EDT
Inactive Policy: Manual
Original Inactive Date: Nov 02, 2024
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
NAICS Code: 334519 - Other Measuring and Controlling Device Manufacturing
Place of Performance: Fredericksburg HCC Fredericksburg, VA 22408 USA
Documents
Tender Notice
Sources-Sought-Notice--36C24624Q1127.pdf