Procurement Summary
Country : USA
Summary : Sources Sought for Fire Suppression System
Deadline : 27 Feb 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 114755278
Document Ref. No. : N6274225FSS
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
Notice of intent to use a brand name product. The Naval Facilities Engineering Systems Command, Pacific (NAVFAC Pacific) is performing a market survey to determine if other potential sources of supply can provide a fire suppression system that has equal performance and listing/approval requirements as the Safespill Ignitable Liquid Drainage Floor Assembly (ILDFA).
Fiscal Year 2025 Military Construction P-2301, HSC-25 Hangar Complex, Andersen Air Force Base, Guam requires a fire suppression system with the following characteristics:
Hollow aluminum extruded floor with a perforated top surface, connected to a trench system to remove any spilled liquid to an acceptable location Approved under FM Approval Standard 6090 Divided into zones with a maximum area of 1, 240 ft2 (115 m2) each Each zone shall have its own solenoid valve, fiber optic liquid detector sensors, and flushing manifold Each flushing manifold requires 50 gallons per minute (GPM) (189 liters per minute) of flushing water The maximum spacing of the trenches shall be 40.37 ft (12.3 m) from the center of each trench Requires the use of prefabricated aluminum trenches The internal slope of the trench is required to be a minimum of 0.5% (0.3°) to ensure liquid drains to the lowest point. The minimum depth of a trench should be 16 inches (404 mm) to allow for proper flow of spilled liquid and piping conduit. The ILDFA floor profiles shall be manufactured out of 6000 series Marine-Grade Aluminum Point load capacity: 96, 000 lbs./(9”x16”) = 666 psi (46 bar) Tie down points shall have a load rating of 10, 000 lbs (4, 536 kg) Floor weight capacity: 350 psi/2.41 mpa Pump skid power requirement: 480V 60 A Control Panel Power Requirement: 120V 10A Flushing system water flow requirement: 200 gpm/720 lpm Flushing system water pressure requirement: 100 psi/7 bar Containment tank capacity: 15, 000 - 70, 000 Gallons
This notification is for market research purposes only to identify if othe...
Active Contract Opportunity
Notice ID : N6274225FSS
Related Notice
Department/Ind. Agency : DEPT OF DEFENSE
Sub-tier : DEPT OF THE NAVY
Major Command : NAVFAC
Sub Command : NAVFAC PACIFIC CMD
Office: NAVFACSYSCOM PACIFIC
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Feb 13, 2025 02:22 pm HST
Original Response Date: Feb 27, 2025 03:00 pm HST
Inactive Policy: 15 days after response date
Original Inactive Date: Mar 14, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: N012 - INSTALLATION OF EQUIPMENT- FIRE CONTROL EQUIPMENT
NAICS Code: 423610 - Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers
Place of Performance: GU USA