Quotation are invited for Supply and install an Automated & Fully closed Tissue Processor Automated Tissue Processor
Supply, installation and operation of the deserted devices- College of Medicine
Supply and install an Automated & Fully closed Tissue Processor Automated Tissue Processor 6640-KY-1009335 1
Technical Specifications:
• Capacity: Not less than 180 cassettes
• Processing chemicals temperature range: RT to 60oC
• Not less than 3 detachable paraffin baths
• Paraffin bath capacity Not less than 3 L
• Paraffin bath temperature setting: 50 to 70oC
• Not less than 10 reagent bottles
• Not less than 2 cleaning solution bottles
• Reagent / Cleaning bottle capacity: not less than 3L
• Spill Trays to collect spilled paraffin and chemicals
• Not less than 3 pre-set protocols
• Touch screen interface
• USB interface for data exchange
• Tissue processor must have
o Retort extraction facility with activated carbon filter
o External safety exhaust attachment
Class A Risk certification
EN ISO 13485 and ISO 9001 quality certification
Tissue processor should be supplied with a compatiable Computer, Not lower
than i7 processor, 11th gen, 2TB SSD, 16 GB RAM with pre installed
acquisition and analysis software and A4 size Laser color printer
Supply and install an integrated portable Electromyography Device for
EMG, NCS and EP studies EA
It should be ideal for
(i) Motor and sensory conduction velocity, F-wave, H-reflex, motor and
sensory inching, motor sensory conduction and other Nerve Conduction
Studies(ii) Repetitive stimulation, jitter EMG Spontaneous activity, interference
curve, motor unit potentials (MUP), macro etc. for Neuromuscular junction
testing
(iii) Blink reflex, sacral reflex, bulbo-cavernous reflex EMG tests
The system should
1. be an integrated portable system for EMG and NCS studies
2. have not less than 2 channels
3. have sampling rate: up to 100 kHz
4. have Software controlled stimulation electrodes
EMG system should be supplied with
i. Computer - latest generation not lower than i7 processor, 1TB SSD, 11th
Gen, 16 GB RAM with pre-installed software for acquisition, analysis and
exchange of the data
ii. Color Laser Printer - A4
iii. Software license and free updates for not less than 4 years
iv. All consumables for training + 150 tests. It should include electrodes,
electrode adhesive paste, Abrasive paste for skin preparation, Medical
transpore tape, EMG needle electrodes, measuring reel etc. for the routine
operation of the device. Bidders must attach the list of items included with
their re-order reference number with their offer.
v. Laser distance meter