Supply of Laboratory Equipment for the Project, Project 2: Establishment of Pharmaceutical... Tender

UNIVERSITY OF THE PHILIPPINES - MANILA has floated a tender for Supply of Laboratory Equipment for the Project, Project 2: Establishment of Pharmaceutical Sciences Services for Clinical Research. The project location is Philippines and the tender is closing on 19 Aug 2024. The tender notice number is BAC3-NIH-PR25794, while the TOT Ref Number is 104892472. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Philippines

Summary : Supply of Laboratory Equipment for the Project, Project 2: Establishment of Pharmaceutical Sciences Services for Clinical Research

Deadline : 19 Aug 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 104892472

Document Ref. No. : BAC3-NIH-PR25794

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : PHP 6725000.00

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Tender are invited for Supply of Laboratory Equipment for the project, Project 2: Establishment of Pharmaceutical Sciences Services for Clinical Research

Procurement Mode : Public Bidding

Classification : Goods

Category : Laboratory Supplies and Equipment

Contract Duration : 0 Day/s

Budget for the Contract : PHP 6, 725, 000.00

Area of Delivery : Metro Manila

Description : Supply of Laboratory Equipment for the project, Project 2: Establishment of Pharmaceutical Sciences Services for Clinical Research



Disintegration Test System



General Specifications:

Instrument dimensions: Width: 35 - 45 cm; Depth: 45 - 55 cm; Height: 40 - 50 cm

Net weight: Maximum of 18 kg



● Number of testing stations: 3 baskets

● Stroke height: 50 - 60 mm

● Stroke frequency: 30 strokes per minute

● Strokes accuracy: ±1 strokes

● Temperature range: Adjustable from 25.0 to 45.0 °C

● Temperature accuracy: ± 0.3 °C

● With safety systems pressure switch

● With thermal switch and thermal fuse

● Testing time range: 00:00:01 to 99:59:59 (hh:mm:ss)

● Stores at least 250 test descriptions (methods) and 30 users

● Complies to United States Pharmacopeia

● Determine disintegration time of tablets, capsules and other dosage forms

● Result report includes disintegration time, actual temperature and number of persisting samples after tested, and evaluation of the test result

● Password protected access throug...

Documents

 Tender Notice