Procurement Summary
Country : USA
Summary : Uv Disinfection Robots
Deadline : 20 Feb 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 96991135
Document Ref. No. : 36C26224Q0601
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
This is a SOURCES SOUGHT ANNOUNCEMENT ONLY. It is neither a solicitation announcement nor a request for proposals or quotes and does not obligate the Government to award a contract. Responses to this source sought notice must be in writing. The purpose of this sources sought announcement is for market research to make appropriate acquisition decisions and to gain knowledge of potential businesses interested and capable of providing the services described below. The Department of Veterans Affairs Network Contracting Office 22 is seeking a contractor to provide XENEX UV Disinfection Robot (MXSUV1-SLXCT) or Equal for Carl T Hayden VA Medical Center, Phoenix, Arizona. The prospective contractor must be able to provide items meeting following characteristics:Salient Characteristics:Must be able to emit full spectrum wavelength of 240-350nmMust accomplish unattended room disinfection to all surfaces within the direct line of site and within the effective distance as stated in the manufacturer labeling. Must be certified to the appropriate safety standards (e.g., IEC 61010-1) by an independent, third-party safety accreditation organization such as Underwriters Laboratory (UL mark) or Intertek Testing Services Must be able to provide all applicable technical specifications, studies, and white papers as evidence of meeting these requirements. Must have a clear description of the available data on the device s new indications or functions related to SARS-CoV-2 or co-existing conditions, such as:Device performance; and Potential risk (e.g., risk of UV exposure)Must have a clear distinction delineating FDA-cleared, FDA-approved, or FDA-authorized.Must have technology that is manufactured by an ISO 13485 registered facility. Must have no warm-up or cool-down delays.Must adhere to the FDA Labeling Requirements, including the following items: a) A caution that UV disinfection will reduce the number of pathogens on the device, but it will not eliminate them complete...
Active Contract Opportunity Notice ID 36C26224Q0601 Related Notice Department/Ind. Agency VETERANS AFFAIRS, DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 262-NETWORK CONTRACT OFFICE 22 (36C262)
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-08:00) PACIFIC STANDARD TIME, LOS ANGELES, USA
Original Published Date: Feb 13, 2024 12:56 pm PST
Original Response Date: Feb 20, 2024 10:00 am PST
Inactive Policy: Manual
Original Inactive Date: Apr 20, 2024
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6515 - MEDICAL AND SURGICAL INSTRUMENTS, EQUIPMENT, AND SUPPLIES
NAICS Code: 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
Place of Performance: Department of Veterans Affairs Phoenix VA Healthcare System Phoenix, AZ 85012 USA
Documents
Tender Notice
36C26224Q0601.docx