VETERANS AFFAIRS, DEPARTMENT OF has floated a tender for Water Purfication System Hcc1 Lab. The project location is USA and the tender is closing on 06 Mar 2024. The tender notice number is 36C24624Q0414, while the TOT Ref Number is 97962298. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : Water Purfication System Hcc1 Lab

Deadline : 06 Mar 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 97962298

Document Ref. No. : 36C24624Q0414

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Description

VA Chesapeake Community Based Outpatient Clinic (CBOC)Chesapeake HCC1Salient CharacteristicsWater Purification System that is capable of producing not less than 200 liters of water per hour, fitted with deionization capabilitiesMODEL MEDICA-R 200Make-up rate @15°C 200 l/hrDelivery flow rate maximum115V, 60Hz 21 l/min @ 45psi (3bar) Inorganics (resistivity @25°C) 10 M -cm (1)Organics (TOC) - typical 250 Softener or use very low RO recovery3Free chlorine: Cl2ppm 0.5 Cylinder of carbon sized correctly to obtain 0.5 Cylinder of carbon sized correctly to obtain 30 20 inch cartridge depth filter or use very low RO recovery (4)Fouling index: FI 20 Back washable media filter with a minimum flow rate of 20 l/minIron/manganese: Fe/Mn ppm 0.05 20 inch cartridge depth filter (5)0.1 Back-washable Fe filter (6)Organics: TOC ppm C 3 Cylinder of carbon sized correctly for TOC demand (4) Temperature: 4 - 40°C (Recommended 15 - 25°C)-Flowrate: (requirement at 15°C) 20 l/minDrain requirements: (gravity fall with air gap) 45 l/minFeedwater pressure: 60psi (4bar) maximum, 30psi (2bar) minimumNotes: 3) Check LSI, increase frequency of acid cleaning, 4) Increase frequency of alkaline cleaning, 5) Please use ELGA Part Numbers LA683 (Filter Housing) and LC172 (Carbon Filter), 6) Increase frequency of acid cleaning Wall mount canister filter will need (Wall backing required)Must include: Installation, Commissioning, TrainingElectrical Requirements Mains Input: 115V, 60HzSystem control voltage (not including pumps and UV) 24V dc Power consumption (peak demand): 2000VAElectrical protection rating 20 amps Noise level during recirculation
Active Contract Opportunity Notice ID 36C24624Q0414 Related Notice Department/Ind. Agency VETERANS AFFAIRS, DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 246-NETWORK CONTRACTING OFFICE 6 (36C246)
General Information
Contract Opportunity Type: Presolicitation (Original)
All Dates/Times are: (UTC-05:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Feb 29, 2024 09:50 am EST
Original Response Date: Mar 06, 2024 10:00 am EST
Inactive Policy: Manual
Original Inactive Date: Mar 11, 2024
Initiative: None

Classification
Original Set Aside:
Product Service Code: 4610 - WATER PURIFICATION EQUIPMENT
NAICS Code: 333310 - Commercial and Service Industry Machinery Manufacturing

Place of Performance:,

Documents

 Tender Notice

36C24624Q0414_2.docx