DEPT OF DEFENSE | DEPT OF THE ARMY has floated a tender for Windtunnel Piping Installation. The project location is USA and the tender is closing on 17 Jan 2025. The tender notice number is W15QKN-25-x-13I9, while the TOT Ref Number is 112634598. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : Windtunnel Piping Installation

Deadline : 17 Jan 2025

Other Information

Notice Type : Tender

TOT Ref.No.: 112634598

Document Ref. No. : W15QKN-25-x-13I9

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Name :Login to see tender_details

Address : Login to see tender_details

Email : Login to see tender_details

Login to see details

Tender Details

Description

This is a Sources Sought (SS) issued by the Army Combat Capabilities Development Command (DEVCOM), Armaments Center (AC), Munitions Engineering & Technology Center (METC) and Aeroballistics Division. This effort is for information to plan an acquisition strategy and contract to install piping to support a hypersonic windtunnel upgrade. Responders to this SS notice are asked to provide capability statements related to experience with the ability to furnish the following requirements for high powered industrial air and pipe systems:

Quantity of (2) 350-PSIG (oil filled screw type) in-door air compressors must be piped approximately 75-feet into quantity of (2) remote out-door air coolers. Pipe must penetrate through concrete wall to go outside from compressor room and must be properly mounted, supported, and sealed. Piping from compressor to cooler must be 2-½-inch diameter, include 2-½-inch hand-operated ball valve at compressor outlet, include mount and support. Confirm ball valve. Ensure pipe fitting and size are correct. Ensure equipment is tested for leaks, properly secured and sealed, and safe for operation. Separate in and out lines must be piped between compressors and coolers to cool the oil. In-line pipe specifications from compressor to cooler must be 2-inch diameter, include 2-inch hand-operated ball valve at compressor outlet, include mount and support. Out-line pipe specifications from cooler to compressor must be 2-inch diameter, include mount and support, include 2-inch hand-operated ball valve at compressor inlet. The in and out lines between compressors and coolers must be manifolded together with a single ½-inch pipe. Oil lines that run outdoors must include heat tracer. Ensure proper fluids are added to the oil lines with required amount of manufactured approved oil. Ensure pipe fitting and size are correct. Ensure equipment is tested for leaks, properly secured and sealed, and safe for operation. Quantity of (2) remote out-door...
Active Contract Opportunity
Notice ID : W15QKN-25-x-13I9
Related Notice
Department/Ind. Agency : DEPT OF DEFENSE
Sub-tier : DEPT OF THE ARMY
Office: W4MK CCDC ARMAMENTS CENTER
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Jan 02, 2025 10:51 am EST
Original Response Date: Jan 17, 2025 04:00 pm EST
Inactive Policy: 15 days after response date
Original Inactive Date: Feb 01, 2025
Initiative: None

Classification
Original Set Aside:
Product Service Code: J045 - MAINT/REPAIR/REBUILD OF EQUIPMENT- PLUMBING, HEATING, AND WASTE DISPOSAL EQUIPMENT
NAICS Code: 23822 - Plumbing, Heating, and Air-Conditioning Contractors

Place of Performance:

Documents

 Tender Notice


Procurement Documents for USA

Access a comprehensive library of standard procurement documents specific to USA. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in USA

Explore Procurement Documents for USA


Want To Bid in This Tender?

Get Local Agent Support in USA and 60 More Countries.

View All The Services


View Tenders By


Publish Tenders


Have Any Dispute With The Purchaser?