Procurement Summary
Country : USA
Summary : Wy Air Circuit Breaker Sh Pp 52A Spare
Deadline : 15 Jul 2024
Other Information
Notice Type : Tender
TOT Ref.No.: 103905871
Document Ref. No. : 140R6024Q0086
Competition : ICB
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
The Bureau of Reclamation, Missouri Basin Region, intends to issue a Commercial Request for Quote (RFQ) for the following Brand Name supplies:a. Standard Equipmenti. Reconditioned, ABB, Model MB-8 Electrically Operated Draw Out CircuitBreaker with Stored Energy Operator1. Reconditioned is defined as: Cleaned, Adjusted, ProperlyLubricated, Free of Defects, Fully Operational, with NoObservable Deficiencies. All contact surfaces should be polishedand all moving parts should move freely.ii. Factory New, ABB, Control Device Assembly, 125 VDC for KLine/MB/VHK Circuit Breaker, Part No. 708392-T07, Installed In Breakerwith standard wiring configuration.iii. Factory New, ABB, Shunt Trip Assembly, 125 VDC for K-Line/MB/VHKCircuit Breaker, Part No. 708393-T07, Installed In Breaker with standardwiring configuration.iv. Factory New, Utility Relay Company, AC-Pro II Kit, Part No. AC2M-MBE-8Includes Mechanical Auto-Reset Actuator and 8000/400A CTs. Installedin Breaker with standard wiring configuration.b. Additional Requirementsi. The fully assembled reconditioned air circuit breaker with installedControl Device Assembly, Shunt Trip Assembly, and AC Pro II Kit shall beaccompanied by a standardized test report demonstrating acceptableresults as outlined in ABB MB-8 Breaker Maintenance Instructions andNETA MTS-2019 (Maintenance and Testing Standards).ii. Electrical Test to be Documented.1. Primary Injection Current-Time Test Results¿ Long-Time Pickup.¿ Long-Time Delay.¿ Short-Time Pickup.¿ Short-Time Delay.¿ Instantaneous Pickup.¿ Instantaneous Delay.2. Insulation Integrity Test Open-Closed.3. Main Contact Resistance Measurements.4. Arcing Contact Gap Measurements.5. Main Contact Dielectric Test.6. CT Polarity Test.7. CT Resistance Test.iii. Visual and Functional Inspections to be Documented.1. Frame.2. Primary Disconnects.3. Secondary Disconnects.4. Arc Chutes.5. Main Contacts.6. Arcing Contacts.7. Interlocks.8. Contact Alignment.9. Mechanism Operation.10. Phase Bar...
Active Contract Opportunity Notice ID 140R6024Q0086 Related Notice Department/Ind. Agency INTERIOR, DEPARTMENT OF THE Sub-tier BUREAU OF RECLAMATION Office GREAT PLAINS REGIONAL OFFICE
General Information
Contract Opportunity Type: Presolicitation (Original)
All Dates/Times are: (UTC-06:00) MOUNTAIN STANDARD TIME, DENVER, USA
Original Published Date: Jul 08, 2024 12:18 pm MDT
Original Response Date: Jul 15, 2024 10:00 am MDT
Inactive Policy: 15 days after response date
Original Inactive Date: Jul 30, 2024
Initiative: None
Classification
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
Product Service Code: 5925 - CIRCUIT BREAKERS
NAICS Code: 335313 - Switchgear and Switchboard Apparatus Manufacturing
Place of Performance:
Documents
Tender Notice